mirror of
https://github.com/DCC-EX/CommandStation-EX.git
synced 2024-11-27 01:56:14 +01:00
AUTOSTART macro
Starts a new task at this point during initialisation. (no need to put a separate start command at the beginning)
This commit is contained in:
parent
5cb427f774
commit
0018ba676b
|
@ -217,6 +217,11 @@ LookList * RMFT2::onCloseLookup=NULL;
|
|||
onCloseLookup->add(operand,progCounter);
|
||||
break;
|
||||
|
||||
case OPCODE_AUTOSTART:
|
||||
// automatically create a task from here at startup.
|
||||
new RMFT2(progCounter);
|
||||
break;
|
||||
|
||||
default: // Ignore
|
||||
break;
|
||||
}
|
||||
|
@ -769,6 +774,7 @@ void RMFT2::loop2() {
|
|||
if (diag) DIAG(F("EXRAIL begin(%d)"),operand);
|
||||
break;
|
||||
|
||||
case OPCODE_AUTOSTART: // Handled only during begin process
|
||||
case OPCODE_PAD: // Just a padding for previous opcode needing >1 operad byte.
|
||||
case OPCODE_SIGNAL: // Signal definition ignore at run time
|
||||
case OPCODE_TURNOUT: // Turnout definition ignored at runtime
|
||||
|
|
2
RMFT2.h
2
RMFT2.h
|
@ -30,7 +30,7 @@
|
|||
enum OPCODE : byte {OPCODE_THROW,OPCODE_CLOSE,
|
||||
OPCODE_FWD,OPCODE_REV,OPCODE_SPEED,OPCODE_INVERT_DIRECTION,
|
||||
OPCODE_RESERVE,OPCODE_FREE,
|
||||
OPCODE_AT,OPCODE_AFTER,
|
||||
OPCODE_AT,OPCODE_AFTER,OPCODE_AUTOSTART,
|
||||
OPCODE_LATCH,OPCODE_UNLATCH,OPCODE_SET,OPCODE_RESET,
|
||||
OPCODE_IF,OPCODE_IFNOT,OPCODE_ENDIF,OPCODE_IFRANDOM,OPCODE_IFRESERVE,
|
||||
OPCODE_DELAY,OPCODE_DELAYMINS,OPCODE_RANDWAIT,
|
||||
|
|
|
@ -60,6 +60,7 @@
|
|||
#define AFTER(sensor_id)
|
||||
#define AMBER(signal_id)
|
||||
#define AT(sensor_id)
|
||||
#define AUTOSTART
|
||||
#define CALL(route)
|
||||
#define CLOSE(id)
|
||||
#define DELAY(mindelay)
|
||||
|
@ -159,6 +160,7 @@ const int StringMacroTracker1=__COUNTER__;
|
|||
#undef AMBER
|
||||
#undef AT
|
||||
#undef AUTOMATION
|
||||
#undef AUTOSTART
|
||||
#undef CALL
|
||||
#undef CLOSE
|
||||
#undef DELAY
|
||||
|
@ -240,6 +242,7 @@ const int StringMacroTracker1=__COUNTER__;
|
|||
#define AFTER(sensor_id) OPCODE_AT,V(sensor_id),OPCODE_AFTER,V(sensor_id),
|
||||
#define AMBER(signal_id) OPCODE_AMBER,V(signal_id),
|
||||
#define AT(sensor_id) OPCODE_AT,V(sensor_id),
|
||||
#define AUTOSTART OPCODE_AUTOSTART,NOP,
|
||||
#define CALL(route) OPCODE_CALL,V(route),
|
||||
#define CLOSE(id) OPCODE_CLOSE,V(id),
|
||||
#define DELAY(ms) OPCODE_DELAY,V(ms/100L),
|
||||
|
|
Loading…