Adjust overcurrent timeouts
This commit is contained in:
parent
10c59028e1
commit
96a46f36c2
|
@ -1 +1 @@
|
|||
#define GITHUB_SHA "devel-overcurrent-202307021833Z"
|
||||
#define GITHUB_SHA "devel-overcurrent-202307022222Z"
|
||||
|
|
|
@ -400,7 +400,7 @@ void MotorDriver::getFastPin(const FSH* type,int pin, bool input, FASTPIN & res
|
|||
// 2. ALERT to OVERLOAD:
|
||||
// Transition happens if different timeouts have elapsed.
|
||||
// If only the fault pin is active, timeout is
|
||||
// POWER_SAMPLE_IGNORE_FAULT_LOW (50ms)
|
||||
// POWER_SAMPLE_IGNORE_FAULT_LOW (100ms)
|
||||
// If only overcurrent is detected, timeout is
|
||||
// POWER_SAMPLE_IGNORE_CURRENT (100ms)
|
||||
// If fault pin and overcurrent are active, timeout is
|
||||
|
@ -413,7 +413,7 @@ void MotorDriver::getFastPin(const FSH* type,int pin, bool input, FASTPIN & res
|
|||
// 3. OVERLOAD to ALERT
|
||||
// Transiton happens when timeout has elapsed, timeout
|
||||
// is named power_sample_overload_wait. It is started
|
||||
// at POWER_SAMPLE_OVERLOAD_WAIT (10ms) at first entry
|
||||
// at POWER_SAMPLE_OVERLOAD_WAIT (40ms) at first entry
|
||||
// to OVERLOAD and then increased by a factor of 2
|
||||
// at further entries to the OVERLOAD condition. This
|
||||
// happens until POWER_SAMPLE_RETRY_MAX (10sec) is reached.
|
||||
|
@ -525,7 +525,7 @@ void MotorDriver::checkPowerOverload(bool useProgLimit, byte trackno) {
|
|||
unsigned long mslpc = (commonFaultPin ? (micros() - globalOverloadStart) : microsSinceLastPowerChange(POWERMODE::OVERLOAD));
|
||||
if (mslpc > power_sample_overload_wait) {
|
||||
// adjust next wait time
|
||||
power_sample_overload_wait *= 4;
|
||||
power_sample_overload_wait *= 2;
|
||||
if (power_sample_overload_wait > POWER_SAMPLE_RETRY_MAX)
|
||||
power_sample_overload_wait = POWER_SAMPLE_RETRY_MAX;
|
||||
// power on test
|
||||
|
|
|
@ -260,13 +260,13 @@ class MotorDriver {
|
|||
|
||||
// Times for overload management. Unit: microseconds.
|
||||
// Base for wait time until power is turned on again
|
||||
static const unsigned long POWER_SAMPLE_OVERLOAD_WAIT = 10000UL;
|
||||
static const unsigned long POWER_SAMPLE_OVERLOAD_WAIT = 40000UL;
|
||||
// Time after we consider all faults old and forgotten
|
||||
static const unsigned long POWER_SAMPLE_ALL_GOOD = 5000000UL;
|
||||
// Time after which we consider a ALERT over
|
||||
static const unsigned long POWER_SAMPLE_ALERT_GOOD = 20000UL;
|
||||
// How long to ignore fault pin if current is under limit
|
||||
static const unsigned long POWER_SAMPLE_IGNORE_FAULT_LOW = 50000UL;
|
||||
static const unsigned long POWER_SAMPLE_IGNORE_FAULT_LOW = 100000UL;
|
||||
// How long to ignore fault pin if current is higher than limit
|
||||
static const unsigned long POWER_SAMPLE_IGNORE_FAULT_HIGH = 5000UL;
|
||||
// How long to wait between overcurrent and turning off
|
||||
|
|