@ -13,7 +13,7 @@ The conventional turnout definition commands and the ```<H>``` responses do not
```<JT>``` command returns a list of turnout ids. The throttle should be uninterested in the turnout technology used but needs to know the ids it can throw/close and monitor the current state.
e.g. response ```<jT 1 17 22 19>```
```<JT 17>`` requests info on turnout 17.\
```<JT 17>`` requests info on turnout 17\
e.g. response ```<jT 17 T "Coal yard exit">``` or ```<jT 17 C "Coal yard exit">``\
(T=thrown, C=closed)\
or ```<jT 17 C "">``` indicating turnout description not given.\
@ -24,7 +24,6 @@ Note: It is still the throttles responsibility to monitor the status broadcasts.
However, I'm not keen on dynamically created/deleted turnouts so I have no intention of providing a command that indicates the turnout list has been updated since the throttle started.
Also note that turnouts marked in EXRAIL with the HIDDEN keyword instead of a "description" will NOT show up in these commands.
Automations/Routes
====================
@ -51,9 +50,9 @@ An *Automation* is a handoff of the last accessed loco id to an EXRAIL AUTOMATIO
Thus an Automation expects a start command with a cab id\
e.g. ```</START 13 3>```
Roster Information
^^^^^^^^^^^^^^^^^^
The ```<JR>``` command requests a list of cab ids from the roster.
e.g. responding ```<jR 3 200 6336>```
or <jR> for none.
@ -63,18 +62,19 @@ An *Automation* is a handoff of the last accessed loco id to an EXRAIL AUTOMATIO
Refer to EXRAIL ROSTER command for function map format.
Obtaining throttle status
^^^^^^^^^^^^^^^^^^^^^^^^^^
```<t cabid>``` Requests a deliberate update on the cab speed/functions in the same format as the cab broadcast.
```<l cabid slot speedbyte functionMap>```
Note that a slot of -1 indicates that the cab is not in the reminders table and this comand will not reserve a slot until such time as the cab is throttled.
COMMANDS TO AVOID
======================
```<f cab func1 func2>``` Use ```<F cab function 1/0>```\
```<f cab func1 func2>``` - Instead Use ```<F cab function 1/0>```\
```<t slot cab speed dir>``` Just drop the slot number\
```<T commands>``` other than ```<T id 0/1>```\
```<s>```\