Added ONOVERLOAD
Added code changes to create ONOVERLOAD command in EXRAIL
This commit is contained in:
parent
9f38dae8ba
commit
e327e0ae8d
15
EXRAIL2.cpp
15
EXRAIL2.cpp
@ -2,7 +2,7 @@
|
||||
* © 2021 Neil McKechnie
|
||||
* © 2021-2023 Harald Barth
|
||||
* © 2020-2023 Chris Harlow
|
||||
* © 2022 Colin Murdoch
|
||||
* © 2022-2023 Colin Murdoch
|
||||
* All rights reserved.
|
||||
*
|
||||
* This file is part of CommandStation-EX
|
||||
@ -94,6 +94,7 @@ LookList * RMFT2::onAmberLookup=NULL;
|
||||
LookList * RMFT2::onGreenLookup=NULL;
|
||||
LookList * RMFT2::onChangeLookup=NULL;
|
||||
LookList * RMFT2::onClockLookup=NULL;
|
||||
LookList * RMFT2::onOverloadLookup=NULL;
|
||||
|
||||
#define GET_OPCODE GETHIGHFLASH(RMFT2::RouteCode,progCounter)
|
||||
#define SKIPOP progCounter+=3
|
||||
@ -175,6 +176,7 @@ LookList* RMFT2::LookListLoader(OPCODE op1, OPCODE op2, OPCODE op3) {
|
||||
onGreenLookup=LookListLoader(OPCODE_ONGREEN);
|
||||
onChangeLookup=LookListLoader(OPCODE_ONCHANGE);
|
||||
onClockLookup=LookListLoader(OPCODE_ONTIME);
|
||||
onOverloadLookup=LookListLoader(OPCODE_ONOVERLOAD);
|
||||
|
||||
|
||||
// Second pass startup, define any turnouts or servos, set signals red
|
||||
@ -986,6 +988,7 @@ void RMFT2::loop2() {
|
||||
case OPCODE_ONGREEN:
|
||||
case OPCODE_ONCHANGE:
|
||||
case OPCODE_ONTIME:
|
||||
case OPCODE_ONOVERLOAD:
|
||||
|
||||
break;
|
||||
|
||||
@ -1140,6 +1143,16 @@ void RMFT2::clockEvent(int16_t clocktime, bool change) {
|
||||
}
|
||||
}
|
||||
|
||||
void RMFT2::powerEvent(char track, bool overload) {
|
||||
// Hunt for an ONOVERLOAD for this item
|
||||
if (Diag::CMD)
|
||||
DIAG(F("Looking for Power event on track : %c"), track);
|
||||
if (overload) {
|
||||
handleEvent(F("POWER"),onOverloadLookup,track);
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
void RMFT2::handleEvent(const FSH* reason,LookList* handlers, int16_t id) {
|
||||
int pc= handlers->find(id);
|
||||
if (pc<0) return;
|
||||
|
@ -1,7 +1,7 @@
|
||||
/*
|
||||
* © 2021 Neil McKechnie
|
||||
* © 2020-2022 Chris Harlow
|
||||
* © 2022 Colin Murdoch
|
||||
* © 2022-2023 Colin Murdoch
|
||||
* © 2023 Harald Barth
|
||||
* All rights reserved.
|
||||
*
|
||||
@ -188,6 +188,7 @@ private:
|
||||
static LookList * onGreenLookup;
|
||||
static LookList * onChangeLookup;
|
||||
static LookList * onClockLookup;
|
||||
static LookList * onOverloadLookup;
|
||||
|
||||
// Local variables - exist for each instance/task
|
||||
RMFT2 *next; // loop chain
|
||||
|
@ -1,6 +1,6 @@
|
||||
/*
|
||||
* © 2020-2022 Chris Harlow. All rights reserved.
|
||||
* © 2022 Colin Murdoch
|
||||
* © 2022-2023 Colin Murdoch
|
||||
* © 2023 Harald Barth
|
||||
*
|
||||
* This file is part of CommandStation-EX
|
||||
@ -93,6 +93,7 @@
|
||||
#undef ONTIME
|
||||
#undef ONCLOCKTIME
|
||||
#undef ONCLOCKMINS
|
||||
#undef ONOVERLOAD
|
||||
#undef ONGREEN
|
||||
#undef ONRED
|
||||
#undef ONTHROW
|
||||
@ -215,6 +216,7 @@
|
||||
#define ONTIME(value)
|
||||
#define ONCLOCKTIME(hours,mins)
|
||||
#define ONCLOCKMINS(mins)
|
||||
#define ONOVERLOAD(track_id)
|
||||
#define ONDEACTIVATE(addr,subaddr)
|
||||
#define ONDEACTIVATEL(linear)
|
||||
#define ONCLOSE(turnout_id)
|
||||
|
@ -1,7 +1,7 @@
|
||||
/*
|
||||
* © 2021 Neil McKechnie
|
||||
* © 2020-2022 Chris Harlow
|
||||
* © 2022 Colin Murdoch
|
||||
* © 2022-2023 Colin Murdoch
|
||||
* © 2023 Harald Barth
|
||||
* All rights reserved.
|
||||
*
|
||||
@ -320,6 +320,7 @@ const HIGHFLASH int16_t RMFT2::SignalDefinitions[] = {
|
||||
#define ONTIME(value) OPCODE_ONTIME,V(value),
|
||||
#define ONCLOCKTIME(hours,mins) OPCODE_ONTIME,V((STRIP_ZERO(hours)*60)+STRIP_ZERO(mins)),
|
||||
#define ONCLOCKMINS(mins) ONCLOCKTIME(25,mins)
|
||||
#define ONOVERLOAD(track_id) OPCODE_ONOVERLOAD,V(TRACK_NUMBER_##track_id),
|
||||
#define ONDEACTIVATE(addr,subaddr) OPCODE_ONDEACTIVATE,V(addr<<2|subaddr),
|
||||
#define ONDEACTIVATEL(linear) OPCODE_ONDEACTIVATE,V(linear+3),
|
||||
#define ONGREEN(signal_id) OPCODE_ONGREEN,V(signal_id),
|
||||
|
@ -4,6 +4,7 @@
|
||||
* © 2021 Fred Decker
|
||||
* © 2020-2023 Harald Barth
|
||||
* © 2020-2021 Chris Harlow
|
||||
* © 2023 Colin Murdoch
|
||||
* All rights reserved.
|
||||
*
|
||||
* This file is part of CommandStation-EX
|
||||
@ -574,6 +575,8 @@ void MotorDriver::checkPowerOverload(bool useProgLimit, byte trackno) {
|
||||
DIAG(F("TRACK %c FAULT PIN detected after %4M. Pause %4M)"), trackno + 'A', mslpc, power_sample_overload_wait);
|
||||
throttleInrush(false);
|
||||
setPower(POWERMODE::OVERLOAD);
|
||||
DIAG(F("Calling EXRAIL"));
|
||||
RMFT2::powerEvent(trackno, true); // Tell EXRAIL we have an overload
|
||||
break;
|
||||
}
|
||||
if (checkCurrent(useProgLimit)) {
|
||||
@ -591,6 +594,8 @@ void MotorDriver::checkPowerOverload(bool useProgLimit, byte trackno) {
|
||||
trackno + 'A', mA, maxmA, mslpc, power_sample_overload_wait);
|
||||
throttleInrush(false);
|
||||
setPower(POWERMODE::OVERLOAD);
|
||||
DIAG(F("Calling EXRAIL"));
|
||||
RMFT2::powerEvent(trackno, true); // Tell EXRAIL we have an overload
|
||||
break;
|
||||
}
|
||||