mirror of
https://github.com/DCC-EX/CommandStation-EX.git
synced 2024-12-23 21:01:25 +01:00
fb6ab85c4a
<a addr subaddr 1> command puts a D=1 into the DCC packet for a DCC Accessory Decoder. This was previously though to correspond to a 'throw' request and a D=0 to a 'close' request. RCN-213 standard identifies that D=1 is 'close' and D=0 is 'throw', so this change allows CS to be configured to invert the states to conform to the RCN-213 definition.
151 lines
6.3 KiB
C
151 lines
6.3 KiB
C
/*
|
|
* COPYRIGHT (c) 2020 Fred Decker
|
|
*
|
|
* This file is part of CommandStation-EX
|
|
*
|
|
* This is free software: you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation, either version 3 of the License, or
|
|
* (at your option) any later version.
|
|
*
|
|
* It is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with CommandStation. If not, see <https://www.gnu.org/licenses/>.
|
|
*/
|
|
|
|
/**********************************************************************
|
|
|
|
The configuration file for DCC-EX Command Station
|
|
|
|
**********************************************************************/
|
|
|
|
/////////////////////////////////////////////////////////////////////////////////////
|
|
// NOTE: Before connecting these boards and selecting one in this software
|
|
// check the quick install guides!!! Some of these boards require a voltage
|
|
// generating resitor on the current sense pin of the device. Failure to select
|
|
// the correct resistor could damage the sense pin on your Arduino or destroy
|
|
// the device.
|
|
//
|
|
// DEFINE MOTOR_SHIELD_TYPE BELOW ACCORDING TO THE FOLLOWING TABLE:
|
|
//
|
|
// STANDARD_MOTOR_SHIELD : Arduino Motor shield Rev3 based on the L298 with 18V 2A per channel
|
|
// POLOLU_MOTOR_SHIELD : Pololu MC33926 Motor Driver (not recommended for prog track)
|
|
// FUNDUMOTO_SHIELD : Fundumoto Shield, no current sensing (not recommended, no short protection)
|
|
// FIREBOX_MK1 : The Firebox MK1
|
|
// FIREBOX_MK1S : The Firebox MK1S
|
|
// IBT_2_WITH_ARDUINO : Arduino Motor Shield for PROG and IBT-2 for MAIN
|
|
// |
|
|
// +-----------------------v
|
|
//
|
|
#define MOTOR_SHIELD_TYPE STANDARD_MOTOR_SHIELD
|
|
/////////////////////////////////////////////////////////////////////////////////////
|
|
//
|
|
// The IP port to talk to a WIFI or Ethernet shield.
|
|
//
|
|
#define IP_PORT 2560
|
|
|
|
/////////////////////////////////////////////////////////////////////////////////////
|
|
//
|
|
// NOTE: Only supported on Arduino Mega
|
|
// Set to false if you not even want it on the Arduino Mega
|
|
//
|
|
#define ENABLE_WIFI true
|
|
|
|
/////////////////////////////////////////////////////////////////////////////////////
|
|
//
|
|
// DEFINE WiFi Parameters (only in effect if WIFI is on)
|
|
//
|
|
// If DONT_TOUCH_WIFI_CONF is set, all WIFI config will be done with
|
|
// the <+> commands and this sketch will not change anything over
|
|
// AT commands and the other WIFI_* defines below do not have any effect.
|
|
//#define DONT_TOUCH_WIFI_CONF
|
|
//
|
|
// WIFI_SSID is the network name IF you want to use your existing home network.
|
|
// Do NOT change this if you want to use the WiFi in Access Point (AP) mode.
|
|
//
|
|
// If you do NOT set the WIFI_SSID and do NOT set the WIFI_PASSWORD,
|
|
// then the WiFi chip will first try to connect to the previously
|
|
// configured network and if that fails fall back to Access Point mode.
|
|
// The SSID of the AP will be automatically set to DCCEX_*.
|
|
// If you DO set the WIFI_SSID then the WiFi chip will try to connect
|
|
// to that (home) network in station (client) mode. If a WIFI_PASSWORD
|
|
// is set (recommended), that password will be used for AP mode.
|
|
// The AP mode password must be at least 8 characters long.
|
|
//
|
|
// Your SSID may not contain ``"'' (double quote, ASCII 0x22).
|
|
#define WIFI_SSID "Your network name"
|
|
//
|
|
// WIFI_PASSWORD is the network password for your home network or if
|
|
// you want to change the password from default AP mode password
|
|
// to the AP password you want.
|
|
// Your password may not conain ``"'' (double quote, ASCII 0x22).
|
|
#define WIFI_PASSWORD "Your network passwd"
|
|
//
|
|
// WIFI_HOSTNAME: You probably don't need to change this
|
|
#define WIFI_HOSTNAME "dccex"
|
|
//
|
|
// WIFI_CHANNEL: If the line "#define ENABLE_WIFI true" is uncommented,
|
|
// WiFi will be enabled (Mega only). The default channel is set to "1" whether
|
|
// this line exists or not. If you need to use an alternate channel (we recommend
|
|
// using only 1,6, or 11) you may change it here.
|
|
#define WIFI_CHANNEL 1
|
|
|
|
/////////////////////////////////////////////////////////////////////////////////////
|
|
//
|
|
// ENABLE_ETHERNET: Set to true if you have an Arduino Ethernet card (wired). This
|
|
// is not for Wifi. You will then need the Arduino Ethernet library as well
|
|
//
|
|
//#define ENABLE_ETHERNET true
|
|
|
|
|
|
/////////////////////////////////////////////////////////////////////////////////////
|
|
//
|
|
// DEFINE STATIC IP ADDRESS *OR* COMMENT OUT TO USE DHCP
|
|
//
|
|
//#define IP_ADDRESS { 192, 168, 1, 200 }
|
|
|
|
|
|
/////////////////////////////////////////////////////////////////////////////////////
|
|
//
|
|
// DEFINE LCD SCREEN USAGE BY THE BASE STATION
|
|
//
|
|
// Note: This feature requires an I2C enabled LCD screen using a Hitachi HD44780
|
|
// controller and a PCF8574 based I2C 'backpack'.
|
|
// To enable, uncomment one of the #define lines below
|
|
|
|
// define LCD_DRIVER for I2C LCD address 0x3f,16 cols, 2 rows
|
|
// #define LCD_DRIVER 0x3F,16,2
|
|
|
|
//OR define OLED_DRIVER width,height in pixels (address auto detected)
|
|
// 128x32 or 128x64 I2C SSD1306-based devices are supported.
|
|
// Also 132x64 I2C SH1106 devices
|
|
// #define OLED_DRIVER 128,32
|
|
|
|
// Define scroll mode as 0, 1 or 2
|
|
#define SCROLLMODE 1
|
|
|
|
/////////////////////////////////////////////////////////////////////////////////////
|
|
//
|
|
// DEFINE TURNOUTS/ACCESSORIES FOLLOW NORM RCN-213
|
|
//
|
|
// According to norm RCN-213 a DCC packet with a 1 is closed/straight
|
|
// and one with a 0 is thrown/diverging. In DCC++ Classic, and in previous
|
|
// versions of DCC++EX, a turnout throw command was implemented in the packet as
|
|
// '1' and a close command as '0'. The #define below makes the states
|
|
// match with the norm. But we don't want to cause havoc on existent layouts,
|
|
// so we define this only for new installations. If you don't want this,
|
|
// don't add it to your config.h.
|
|
//#define DCC_TURNOUTS_RCN_213
|
|
|
|
// The following #define likewise inverts the behaviour of the <a> command
|
|
// for triggering DCC Accessory Decoders, so that <a addr subaddr 0> generates a
|
|
// DCC packet with D=1 (close turnout) and <a addr subaddr 1> generates D=0
|
|
// (throw turnout).
|
|
//#define DCC_ACCESSORY_RCN_213
|
|
|
|
/////////////////////////////////////////////////////////////////////////////////////
|