Railcom implementation notes, Chris Harlow Oct 2024
|
|
|
|
Railcom support is in 3 parts
|
|
1. Generation of the DCC waveform with a Railcom cutout.
|
|
2. Accessing the railcom feedback from a loco using hardware detectors
|
|
3. Utilising the feedback to do something useful.
|
|
|
|
DCC Waveform Railcom cutout depends on using suitable motor shields (EX8874 primarily) as the standard Arduino shield is not suitable. (Too high resistance during cutout)
|
|
The choice of track management also depends on wiring all the MAIN tracks to use the same signal and brake pins. This allows separate track power management but prevents switching a single track from MAIN to PROG or DC...
|
|
Some CPUs require very specific choice of brake pins etc to match their internal timer register architecture.
|
|
|
|
- MEGA.. The default shield setting for an EX8874 is suitable for Railcom on Channel A (MAIN)
|
|
- ESP32 .. not yet supported.
|
|
- Nucleo ... TBA
|
|
|
|
Enabling the Railcom Cutout requires a `<C RAILCOM ON>` command. This can be added to myAutomation using `PARSE("<C RAILCOM ON>")`
|
|
Code to calculate the cutout position and provide synchronization for the sampling is in `DCCWaveform.cpp` (not ESP32)
|
|
and in general a global search for "railcom" will show all code changes that have been made to support this.
|
|
|
|
Code to actually implement the timing of the cutout is highly cpu dependent and can be found in the various implementations of `DCCTimer.h`. At this time only `DCCTimerAVR.cpp`has implemented this.
|
|
|
|
|
|
Reading Railcom data:
|
|
A new HAL handler (`IO_I2CRailcom.h`) has been added to process input from a 32-block railcom collecter which operates over I2C. The collector and its readers sit between the CS and the track and collect railcom data from locos during the cutout.
|
|
The Collector device removes 99.9% of the railcom traffic and returns just a summary of what has changed since the last cutout.
|
|
After the cutout the HAL driver reads the Collector summary over I2C and passes the raw data to the CS logic (`Railcom.cpp`) for analysis.
|
|
|
|
Each 32-block reader is described in myAutomation like `HAL(I2CRailcom,10000,32,0x08)` which will assign 32 blocks on i2c address 0x08 with vpin numbers 10000 and 10031. If you only use fewer channel in the collector, you can assign fewer pins here.
|
|
(Implementation notes.. you may have multiple collectors, each one will requite a HAL line to define its i2c address and vpins to represent block numbers.)
|
|
|
|
Making use of Railcom data
|
|
|
|
Exrail has two additional event handlers which can capture locos entering and exiting blocks. These handlers are started with the loco information already set, so for example:
|
|
```
|
|
ONBLOCKENTER(10000)
|
|
// a loco has entered block 10000
|
|
FON(0) // turn the light on
|
|
FON(1) // make a lot of noise
|
|
SPEED(20) // slow down
|
|
DONE
|
|
|
|
ONBLOCKEXIT(10000)
|
|
// a loco has left block 10000
|
|
FOFF(0) // turn the light off
|
|
FOFF(1) // stop the noise
|
|
SPEED(50) // speed up again
|
|
DONE
|
|
```
|
|
|
|
Note that the Railcom interpretation code is capable of detecting multiple locos in the same block at the same time and will create separate exrail tasks for each one.
|
|
There is however one minor loophole in the block exit logic...
|
|
If THREE or more locos are in the same block and ONE of them leaves, then ONBLOCKEXIT will not fire until
|
|
EITHER - The leaving loco enters another railcom block
|
|
OR - only ONE loco remains in the block just left.
|
|
|
|
To further support block management in railcom, two additional serial commands are available
|
|
|
|
`<K block loco >` to simulate a loco entering a block, and trigger any ONBLOCKENTER
|
|
`<k block loco >` to simulate a loco leaving a block, and trigger and ONBLOCKEXIT
|
|
|
|
|
|
Reading CV values on MAIN.
|
|
|
|
Railcom allows for the facility to read loco cv values while on the main track. This is considerably faster than PROG track access but depends on the loco being in a Railcom monitored block.
|
|
|
|
To read from PROG Track we use `<R cv>` response is `<r value>`
|
|
|
|
To read from MAIN track use `<r loco cv>`
|
|
response is `<r loco cv value>`
|
|
|
|
|